# HOISTING
> MSHA accident `220230340023` · 01/27/2023 · Nevada Gold Mines LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Barrick Nevada Holding LLC; Newmont USA Limited
- **Operator:** Nevada Gold Mines LLC
- **Mine:** [2602286](https://api.morvs.ai/mine/2602286)
## Narrative

While performing daily hoist checks the hoist drive was found to have 2 blown fuses, which shorted out the SCR. This caused an outage lasting longer than 30 minutes. Electricians were notified and they replaced the fuses and put the hoist back into service.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · MORVS · CC0 1.0*