# HOISTING
> MSHA accident `220262190009` · 07/29/2026 · Hecla Limited
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Hecla Mining Company
- **Operator:** Hecla Limited
- **Mine:** [1000088](https://api.morvs.ai/mine/1000088)
## Narrative

Hoistman was signaled to move north conveyance into position for weekly cage inspections at the #2 shaft top station and the hoist tripped out on YA1 Converter fault. Electricians and an ABB technician performed troubleshooting and identified the cause to be a faulty breaker.

---