# Amputations at Odyssey Industrial Systems, LLC
> OSHA SIR `2015099827` · 9/4/2015 · HOUSTON, TEXAS
## Severity
- **1 amputation**
- **Body part:** Fingertip(s)
- **Nature of injury:** Amputations
## Cause
- **Event:** Caught in running equipment or machinery during regular operation
- **Source:** Brake presses
## Employer
- **Name:** Odyssey Industrial Systems, LLC
- **Location:** 11669 Brittmoore Park Dr., HOUSTON, TEXAS, 77041
- **NAICS:** 332710
- **Jurisdiction:** 1
## Narrative

While working on a metal part on a brake press, the employee amputated the tip of his left index finger.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*