# Heat (thermal) burns, unspecified at Lee Brass Foundry LLC
> OSHA SIR `2016054599` · 5/24/2016 · ANNISTON, ALABAMA
## Severity
- **1 hospitalization**
- **Body part:** Nonclassifiable
- **Nature of injury:** Heat (thermal) burns, unspecified
## Cause
- **Event:** Explosion, n.e.c.
- **Source:** Furnaces, heaters
## Employer
- **Name:** Lee Brass Foundry LLC
- **Location:** 1800 Golden Spring Road, ANNISTON, ALABAMA, 36207
- **NAICS:** 331523
- **Jurisdiction:** 1
## Narrative

Three employees were using a pry bar to free a bridge that occurred on a furnace when the furnace exploded. One of the employees was hospitalized with severe burns.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*