# Amputations at Keane Group, Sucessor of Trican Well Services
> OSHA SIR `20161211790` · 12/19/2016 · CLARINGTON, OHIO
## Severity
- **1 amputation**
- **Body part:** Finger(s), fingernail(s), n.e.c.
- **Nature of injury:** Amputations
## Cause
- **Event:** Caught in running equipment or machinery during maintenance, cleaning
- **Source:** Pumps
## Employer
- **Name:** Keane Group, Sucessor of Trican Well Services
- **Location:** XTO Energy Monroe North Pad Natural Gas Wellsite, CLARINGTON, OHIO, 43915
- **NAICS:** 213112
- **Jurisdiction:** 1
## Narrative

An employee was attempting to repair a small portable pneumatic barrel pump that appeared to be frozen. The employee had his left ring finger inside the pump plunger when it activated, amputating his left ring finger.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*