# Second degree chemical burns and corrosions at DanoneWave
> OSHA SIR `2017054004` · 5/2/2017 · DALLAS, TEXAS
## Severity
- **1 hospitalization**
- **Body part:** Nonclassifiable
- **Nature of injury:** Second degree chemical burns and corrosions
## Cause
- **Event:** Exposure through intact skin, eyes, or other exposed tissue
- **Source:** Chemicals and chemical products, unspecified
## Employer
- **Name:** DanoneWave
- **Location:** 3333 Dan Morton Dr, DALLAS, TEXAS, 75236
- **NAICS:** 311511
- **Jurisdiction:** 1
## Narrative

A sanitation employee was splashed with corrosive chemicals while attempting to prime a chemical pump resulting in second degree burns.

---