# Third or fourth degree heat (thermal) burns at Honeywell Aerospace
> OSHA SIR `2017076126` · 7/4/2017 · TULSA, OKLAHOMA
## Severity
- **1 hospitalization**
- **Body part:** Multiple body parts, n.e.c.
- **Nature of injury:** Third or fourth degree heat (thermal) burns
## Cause
- **Event:** Explosion of nonpressurized vapors, gases, or liquids
- **Source:** Chemical products, n.e.c.
## Employer
- **Name:** Honeywell Aerospace
- **Location:** 6930 N Lakewood Ave, TULSA, OKLAHOMA, 74117
- **NAICS:** 336413
- **Jurisdiction:** 1
## Narrative

An employee was getting rags to wipe down a part that had just been dipped in LORCOAT when an explosion and fire occurred, causing second and third degree burns to the employee's arms, second degree burns to the neck, and first and second degree burns to the head. The employee was hospitalized.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*