# Second degree heat (thermal) burns at CHALMETTE REFINING LLC
> OSHA SIR `2017099339` · 9/29/2017 · CHALMETTE, LOUISIANA
## Severity
- **1 hospitalization**
- **Body part:** Nonclassifiable
- **Nature of injury:** Second degree heat (thermal) burns
## Cause
- **Event:** Contact with hot objects or substances
- **Source:** Steam, vapors-nonchemical
- **Secondary source:** Special process machinery, n.e.c.
## Employer
- **Name:** CHALMETTE REFINING LLC
- **Location:** 500 W. ST. BERNARD HWY, CHALMETTE, LOUISIANA, 70044
- **NAICS:** 324110
- **Jurisdiction:** 1
## Narrative

An employee received second degree burns from steam from the coker drum while performing housekeeping duties.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*