# Amputations at Goodman Manufacturing Company, L.P.
> OSHA SIR `20171110623` · 11/4/2017 · HOUSTON, TEXAS
## Severity
- **1 amputation, 1 hospitalization**
- **Body part:** Hand(s), n.e.c.
- **Nature of injury:** Amputations
## Cause
- **Event:** Caught in running equipment or machinery during maintenance, cleaning
- **Source:** Extruding, injecting, forming, molding machinery, n.e.c.
## Employer
- **Name:** Goodman Manufacturing Company, L.P.
- **Location:** 3300 W. 11th St., HOUSTON, TEXAS, 77041
- **NAICS:** 333415
- **Jurisdiction:** 1
## Narrative

An employee was clearing a jammed coil on a roll-forming machine when the die came down and crushed his left hand. He was hospitalized, and his left hand was surgically amputated.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*