# Amputations at Accura Systems, Inc.
> OSHA SIR `2018054744` · 5/15/2018 · SUNNYVALE, TEXAS
## Severity
- **1 amputation**
- **Body part:** Finger(s), fingernail(s), n.e.c.
- **Nature of injury:** Amputations
## Cause
- **Event:** Compressed or pinched by shifting objects or equipment
- **Source:** Windows, openings
- **Secondary source:** Product testing, inspecting, and diagnostic machinery, n.e.c.
## Employer
- **Name:** Accura Systems, Inc.
- **Location:** 326 Clay Road, SUNNYVALE, TEXAS, 75182
- **NAICS:** 332321
- **Jurisdiction:** 1
## Narrative

An employee was helping coworkers place a window in a leak test chamber when his right index finger was caught between the opening of the test chamber and the window, resulting in a finger amputation.

---