# Amputations at Sensus USA, Inc.
> OSHA SIR `2018088637` · 8/21/2018 · DUBOIS, PENNSYLVANIA
## Severity
- **1 amputation**
- **Body part:** Fingertip(s)
- **Nature of injury:** Amputations
## Cause
- **Event:** Compressed or pinched by shifting objects or equipment
- **Source:** Parts and materials, unspecified
- **Secondary source:** Product testing, inspecting, and diagnostic machinery, n.e.c.
## Employer
- **Name:** Sensus USA, Inc.
- **Location:** 805 Liberty Boulevard, DUBOIS, PENNSYLVANIA, 15801
- **NAICS:** 332439
- **Jurisdiction:** 1
## Narrative

An employee was clamping a cast iron gas meter housing unit into a hydrostatic test unit. While actuating the clamping mechanism, he was holding the body with his right hand. As the clamping mechanism was clamping, the cap on the outlet end (left side of the body) shifted. At this point, he grabbed the body and cap to prevent it from falling out of the testing machine. His left thumb then became caught between the cap and the hydrostatic test clamping mechanism, causing a partial amputation of his thumb tip.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*