# Fractures at Turner Sign Systems, Inc.
> OSHA SIR `2020010843` · 1/26/2020 · DALLAS, TEXAS
## Severity
- **1 hospitalization**
- **Body part:** Pelvis
- **Nature of injury:** Fractures
## Cause
- **Event:** Caught in running equipment or machinery during regular operation
- **Source:** Garage doors
## Employer
- **Name:** Turner Sign Systems, Inc.
- **Location:** 5033 Lemmon Avenue, DALLAS, TEXAS, 75209
- **NAICS:** 339950
- **Jurisdiction:** 1
## Narrative

An employee was working inside an enclosure on the overhead roll-up garage door. The power to the door was turned on and the employee was crushed between the door and a wall, suffering four broken pelvic bones. The door had been turned off but not locked/tagged out at the time of the incident.

---