# Electrical burns, unspecified at Forestry Resources, LLC
> OSHA SIR `2020054950` · 5/28/2020 · CROSS CITY, FLORIDA
## Severity
- **1 hospitalization**
- **Body part:** Hand(s), unspecified
- **Nature of injury:** Electrical burns, unspecified
## Cause
- **Event:** Direct exposure to electricity, greater than 220 volts
- **Source:** Sealing, stapling machinery
## Employer
- **Name:** Forestry Resources, LLC
- **Location:** 452 SW 10th St, CROSS CITY, FLORIDA, 32628
- **NAICS:** 333112
- **Jurisdiction:** 1
## Narrative

An employee was checking a top seal machine to determine why the bags were not heat sealing properly when he contacted an energized 240 volt, 20 amp electrical wire and received electrical burns to his right hand.

---