# Heat (thermal) burns, unspecified at H & H General Excavating
> OSHA SIR `2020065424` · 6/10/2020 · SPRING GROVE, PENNSYLVANIA
## Severity
- **1 hospitalization**
- **Body part:** Upper and lower limb(s)
- **Nature of injury:** Heat (thermal) burns, unspecified
## Cause
- **Event:** Ignition of vapors, gases, or liquids
- **Source:** Gasoline, diesel fuel, jet fuel
## Employer
- **Name:** H & H General Excavating
- **Location:** 228 South Main Street, SPRING GROVE, PENNSYLVANIA, 17362
- **NAICS:** 333112
- **Jurisdiction:** 1
## Narrative

An employee had been operating a gasoline powered water pump. When the water pump ran out of gasoline, the employee went to add gasoline and the gasoline fumes ignited. The employee was burned on the left hand, left arm, and left leg.

---