# Chemical burns and corrosions, unspecified at JAC Products, Inc.
> OSHA SIR `2020065561` · 6/15/2020 · FRANKLIN, GEORGIA
## Severity
- **1 hospitalization**
- **Body part:** Chest, except internal location of diseases or disorders
- **Nature of injury:** Chemical burns and corrosions, unspecified
## Cause
- **Event:** Inhalation of harmful substance-single episode
- **Source:** Acids, n.e.c.
## Employer
- **Name:** JAC Products, Inc.
- **Location:** 266 Mary Johnson Drive, FRANKLIN, GEORGIA, 30217
- **NAICS:** 331316
- **Jurisdiction:** 1
## Narrative

An employee was holding down the hose pump to transfer chemicals from the dip tank to a tote. The employee was exposed via inhalation to phosphoric acid resulting in chemical burns to the lung.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*