# Fractures at Northeast Precast
> OSHA SIR `2020098732` · 9/14/2020 · MOUNT POCONO, PENNSYLVANIA
## Severity
- **1 hospitalization**
- **Body part:** Multiple body parts, n.e.c.
- **Nature of injury:** Fractures
## Cause
- **Event:** Other fall to lower level, unspecified
- **Source:** Manlifts
- **Secondary source:** Walls
## Employer
- **Name:** Northeast Precast
- **Location:** 145 Market Way, MOUNT POCONO, PENNSYLVANIA, 18344
- **NAICS:** 238120
- **Jurisdiction:** 1
## Narrative

On Monday, September 14, 2020, at approximately 10:40 AM, employees were setting precast concrete wall panels (45' x 12'). A lift was used to pickup braces. The frame of the lift contacted a wall brace causing a concrete panel to fall. As the panel fell, it struck a manlift that was being used to install braces. As the manlift fell, it struck the lift causing an employee in the manlift to be ejected. He was wearing a personal fall arrest harness at the time. The employee sustained a fractured right femur and fractured ribs and was hospitalized.

---