# Electrical burns, unspecified at Novinium, Inc.
> OSHA SIR `2021065199` · 6/25/2021 · BRIGHTON, COLORADO
## Severity
- **1 hospitalization**
- **Body part:** Hand(s), unspecified
- **Nature of injury:** Electrical burns, unspecified
## Cause
- **Event:** Indirect exposure to electricity, unspecified
- **Source:** Handtools-power not determined, n.e.c.
- **Secondary source:** Electric parts, unspecified
## Employer
- **Name:** Novinium, Inc.
- **Location:** 13230 Dillon St, BRIGHTON, COLORADO, 80601
- **NAICS:** 221122
- **Jurisdiction:** 1
## Narrative

An employee was assisting a crew in de-energizing a radial section of cable. The employee was switching cables to isolate a section he was working on when a probe contacted a cable, resulting in a shock and burns to both hands.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*