# Electrocutions, electric shocks at KAY CONCRETE MATERIALS
> OSHA SIR `2021075678` · 7/12/2021 · AURORA, MISSOURI
## Severity
- **1 hospitalization**
- **Body part:** BODY SYSTEMS
- **Nature of injury:** Electrocutions, electric shocks
## Cause
- **Event:** Indirect exposure to electricity, greater than 220 volts
- **Source:** Cement truck, concrete mixer truck
- **Secondary source:** Power lines, transformers, convertors
## Employer
- **Name:** KAY CONCRETE MATERIALS
- **Location:** 117 Morgan Ave, AURORA, MISSOURI, 65605
- **NAICS:** 327320
- **Jurisdiction:** 1
## Narrative

An employee was unloading concrete from a ready-mix truck. The employee was leaning on the truck's fender and had a remote control for the truck in his hand. The pumper that he was feeding into made contact with an overhead power line; the employee suffered a whole-body shock.

---