# Electrical burns, unspecified at MasTec Services Company, Inc.
> OSHA SIR `20211211126` · 12/29/2021 · JACKSON, GEORGIA
## Severity
- **1 hospitalization**
- **Body part:** Upper and lower limb(s)
- **Nature of injury:** Electrical burns, unspecified
## Cause
- **Event:** Indirect exposure to electricity, greater than 220 volts
- **Source:** Wire, cables-nonelectrical
- **Secondary source:** Nonclassifiable
## Employer
- **Name:** MasTec Services Company, Inc.
- **Location:** Electric Utility Right of Way 1838-1918 GS SR-36, JACKSON, GEORGIA, 30233
- **NAICS:** 237110
- **Jurisdiction:** 1
## Narrative

An employee was on the ground working on a de-energized-by-design pole guy wire. The guy wire became energized by an overhead electric source. The employee sustained electric burns to their left hand and right knee and was hospitalized for treatment.

---