# Amputations at Haliburton Energy Services
> OSHA SIR `2023054142` · 5/9/2023 · ZANESVILLE, OHIO
## Severity
- **1 amputation**
- **Body part:** Fingertip(s)
- **Nature of injury:** Amputations
## Cause
- **Event:** Compressed or pinched by shifting objects or equipment
- **Source:** Centrifuges
## Employer
- **Name:** Haliburton Energy Services
- **Location:** 4999 East Pointe Drive, ZANESVILLE, OHIO, 43701
- **NAICS:** 213112
- **Jurisdiction:** 1
## Narrative

Two employees were completing a post-job inspection of a centrifuge. One employee rotated the centrifuge rotating assembly to test if it could be turned by hand. The injured employee went to stop the rotating assembly when their left little finger was caught between the belt and pulley system. The employee sustained an open, non-displaced distal phalanx fracture and a fingertip amputation to the left little finger.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*