# Chemical burns, corrosions  degree unspecified at NexTier Completion Solutions Inc.
> OSHA SIR `2024010031` · 1/2/2024 · MARSHALL, TEXAS
## Severity
- **1 hospitalization**
- **Body part:** Head and neck
- **Nature of injury:** Chemical burns, corrosions  degree unspecified
## Cause
- **Event:** Exposure through intact tissue
- **Source:** Corrosive bases  unspecified
- **Secondary source:** Source, secondary source  unspecified
## Employer
- **Name:** NexTier Completion Solutions Inc.
- **Location:** 5604 Medco Drive, MARSHALL, TEXAS, 75670
- **NAICS:** 213112
- **Jurisdiction:** 1
## Narrative

Employees were flushing a chemical line at a job site. As an employee was unplugging a hose connection, residual pressure caused caustic liquids to spray under his face shield, resulting in chemical burns to the face and neck that required hospitalization.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*