# Amputations, avulsions, enucleations  unspecified at Mallard Manufacturing
> OSHA SIR `2024010088` · 1/4/2024 · STERLING, ILLINOIS
## Severity
- **1 amputation**
- **Body part:** Other finger(s)  n.e.c.
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Struck by running powered equipment  during maintenance, cleaning, testing
- **Source:** Metal, woodworking, and special material machinery  unspecified
- **Secondary source:** Secondary source not applicable
## Employer
- **Name:** Mallard Manufacturing
- **Location:** 101 Mallard Rd, STERLING, ILLINOIS, 61081
- **NAICS:** 339999
- **Jurisdiction:** 1
## Narrative

An employee was conducting service on a bearing insert machine. A proximity sensor activated, causing the machine to cycle. A cylinder came down on the employee's finger resulting in a partial amputation. The machine was energized at the time.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*