# Amputations, avulsions, enucleations  unspecified at Drummond Press, Inc.
> OSHA SIR `2024010781` · 1/25/2024 · JACKSONVILLE, FLORIDA
## Severity
- **1 amputation, 1 hospitalization**
- **Body part:** Finger or thumb tip(s), nail(s)
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Struck by running powered equipment  unspecified
- **Source:** Industrial printing machinery
- **Secondary source:** Machine guards
## Employer
- **Name:** Drummond Press, Inc.
- **Location:** 2472 Dennis Street, JACKSONVILLE, FLORIDA, 32204
- **NAICS:** 323111
- **Jurisdiction:** 1
## Narrative

At 4:23 p.m. on January 25, 2024, an employee lifted the guard on a press he was working on. While the guard was lifted, the hydraulic piston on the guard failed, causing the guard to collapse onto the employee's right thumb and amputate the tip. The employee was hospitalized.

---