# Amputations, avulsions, enucleations  unspecified at Siemens Smart Infrastructure Inc.
> OSHA SIR `2024010802` · 1/25/2024 · DALLAS, TEXAS
## Severity
- **1 amputation**
- **Body part:** Finger or thumb tip(s), nail(s)
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Caught or wedged between objects  nonrunning
- **Source:** Heating, cooling, cleaning, and waste handling machinery  n.e.c.
- **Secondary source:** Secondary source not applicable
## Employer
- **Name:** Siemens Smart Infrastructure Inc.
- **Location:** 3200 Buckley Avenue, DALLAS, TEXAS, 75205
- **NAICS:** 238220
- **Jurisdiction:** 1
## Narrative

An employee was servicing an air-handling unit. After he turned off the power, the belt and pulley caught his left hand, causing the amputation of his index fingertip.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*