> OSHA SIR `2024021345` · 2/12/2024 · WATFORD CITY, NORTH DAKOTA
## Severity
- **1 hospitalization**
- **Body part:** Arm(s)  unspecified
- **Nature of injury:** Fractures
## Cause
- **Event:** Caught, entangled in running powered equipment  normal operation
- **Source:** Rotary system equipment
- **Secondary source:** Safety and environmental factors and conditions  unspecified
## Employer
- **Name:** ND Energy Services
- **Location:** 47.732975, -102.884312, WATFORD CITY, NORTH DAKOTA, 58854
- **NAICS:** 213112
- **Jurisdiction:** 1
## Narrative

An employee was in a rod basket while moving rods from a well bore. He had his hand on a cable above the rotating rod when his glove or sleeve got caught in the rotating rod stand, resulting in a broken arm.

---