# Amputations, avulsions, enucleations  unspecified at Pro Frac Services
> OSHA SIR `2024021680` · 2/23/2024 · BLANCHARD, LOUISIANA
## Severity
- **1 amputation**
- **Body part:** Other finger(s)  n.e.c.
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Struck by running powered equipment  during maintenance, cleaning, testing
- **Source:** Oil well pump
- **Secondary source:** Secondary source not applicable
## Employer
- **Name:** Pro Frac Services
- **Location:** 32 degrees 35'33'' N93 degrees 56'38''W, BLANCHARD, LOUISIANA, 71009
- **NAICS:** 211111
- **Jurisdiction:** 1
## Narrative

An employee was conducting maintenance on a pipe and was using a T-bar tool to secure the retainer cap on a pump. The employee's left index finger was caught in the rotating pump, resulting in a partial amputation.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*