# Amputations, avulsions, enucleations  unspecified at T&L Automatics, Inc.
> OSHA SIR `2024054694` · 5/29/2024 · ROCHESTER, NEW YORK
## Severity
- **1 amputation**
- **Body part:** Other finger(s)  n.e.c.
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Caught, entangled in running powered equipment  normal operation
- **Source:** Metal, woodworking, and special material machinery  unspecified
- **Secondary source:** Secondary source not applicable
## Employer
- **Name:** T&L Automatics, Inc.
- **Location:** 770 Emerson Street, ROCHESTER, NEW YORK, 14613
- **NAICS:** 332710
- **Jurisdiction:** 1
## Narrative

An employee was operating the choke tube stamper when the metal plate rolled over his finger resulting in an amputation.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*