# Fractures at Anchor Drilling, Inc
> OSHA SIR `2024065728` · 6/26/2024 · BELLAIRE, TEXAS
## Severity
- **1 hospitalization**
- **Body part:** Leg(s)  unspecified
- **Nature of injury:** Fractures
## Cause
- **Event:** Struck by running powered equipment  during maintenance, cleaning, testing
- **Source:** Bucket, front-end, and pay loaders
- **Secondary source:** Augers  except conveyor
## Employer
- **Name:** Anchor Drilling, Inc
- **Location:** 6909 Avenue B, BELLAIRE, TEXAS, 77401
- **NAICS:** 238910
- **Jurisdiction:** 1
## Narrative

An employee was changing a bolt on the beller (a drilling tool) that was attached to an auger drive motor on a track loader. The auger drive motor spun, causing the beller to spin and strike the employee's legs. The employee sustained a broken right leg and bruises on the left leg.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*