# Amputations, avulsions, enucleations  unspecified at AHF Parent Holding Inc.
> OSHA SIR `2024088047` · 8/29/2024 · LANCASTER, PENNSYLVANIA
## Severity
- **1 amputation, 1 hospitalization**
- **Body part:** Finger or thumb tip(s), nail(s)
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Struck by running powered equipment  during maintenance, cleaning, testing
- **Source:** Machinery  unspecified
- **Secondary source:** Drives, belts, chains
## Employer
- **Name:** AHF Parent Holding Inc.
- **Location:** 1067 Dillerville Road, LANCASTER, PENNSYLVANIA, 17603
- **NAICS:** 326199
- **Jurisdiction:** 1
## Narrative

An employee was conducting a paper test after changing a roll on the assembly line when paper began jamming at the outfeed conveyor. As the employee was clearing the jam, their right thumb was caught in the nip point between a belt and a drive gear resulting in degloving injuries. The tip of their thumb was surgically amputated.

---