# Intracranial injuries with skull fractures at Ken's Electrical Service, Inc.
> OSHA SIR `2024098531` · 9/13/2024 · PENSACOLA, FLORIDA
## Severity
- **1 hospitalization**
- **Body part:** Brain
- **Nature of injury:** Intracranial injuries with skull fractures
## Cause
- **Event:** Nonroadway noncollision  vehicle overturn
- **Source:** Hoists, lifts  scissor, telescoping
- **Secondary source:** Secondary source not applicable
## Employer
- **Name:** Ken's Electrical Service, Inc.
- **Location:** W. Street Business Park, PENSACOLA, FLORIDA, 32505
- **NAICS:** 238210
- **Jurisdiction:** 1
## Narrative

Two employees on a scissor lift were doing electrical work outside the building. The lift moved from a concrete surface to a gravel surface, lost balance, and tipped. The employees fell from the lift to the gravel. One employee was hospitalized due to a fractured skull, swelling of the brain, and loss of consciousness. The second employee sustained minor injuries and was not hospitalized.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*