# Amputations, avulsions, enucleations  unspecified at Flextronics America, LLC
> OSHA SIR `2024098836` · 9/22/2024 · AUSTIN, TEXAS
## Severity
- **1 amputation**
- **Body part:** Finger or thumb tip(s), nail(s)
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Struck by running powered equipment  during maintenance, cleaning, testing
- **Source:** Conveyors  unspecified
- **Secondary source:** Gloves, handguards  except disposable, electric insulating
## Employer
- **Name:** Flextronics America, LLC
- **Location:** 12455 RESEARCH BOULEVARD, AUSTIN, TEXAS, 78759
- **NAICS:** 334418
- **Jurisdiction:** 1
## Narrative

An employee was working to free a conveyor pallet that was jammed under a conveyor. Their right glove got caught in the conveyor and they sustained partial amputations to the index and little fingertips.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*