# Amputations, avulsions, enucleations  unspecified at SPIRIT AEROSYSTEMS, INC.
> OSHA SIR `2025010376` · 1/13/2025 · WICHITA, KANSAS
## Severity
- **1 amputation**
- **Body part:** Finger or thumb tip(s), nail(s)
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Contact incidents  unspecified
- **Source:** Metal, woodworking, and special material machinery  unspecified
- **Secondary source:** Source, secondary source  unspecified
## Employer
- **Name:** SPIRIT AEROSYSTEMS, INC.
- **Location:** 3801 S. OLIVER ST., WICHITA, KANSAS, 67210
- **NAICS:** 336413
- **Jurisdiction:** 1
## Narrative

An employee was installing a rail on a machine. The roller pack was locked up, causing the chuck to not move. While manually removing the chuck, the rails were damaged. As a result, both the roller pack and the rail needed to be replaced. A fixed magnet from above the rail pulled the rail up and rolled it, pinching the employee's thumb between the rail and the magnet when he tried to install the new rail back to the position. The right thumb tip was amputated.

---