# Amputations, avulsions, enucleations  unspecified at Dragon Products LTD
> OSHA SIR `2025021797` · 2/25/2025 · LIBERTY, TEXAS
## Severity
- **1 amputation**
- **Body part:** Thumb(s)
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Caught or wedged between objects  nonrunning
- **Source:** Nails, brads, tacks, spikes
- **Secondary source:** Source, secondary source  unspecified
## Employer
- **Name:** Dragon Products LTD
- **Location:** 205 FM 19091, LIBERTY, TEXAS, 77575
- **NAICS:** 332420
- **Jurisdiction:** 1
## Narrative

An employee was inserting a pin into a slot to secure two sections of platform support legs (square tubing). The employee's right thumb was pinched in the slot with the pin, resulting in a partial amputation of the distal phalangeal tuft and an open fracture.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*