# Fractures at Prism Electric Inc.
> OSHA SIR `2025032092` · 3/5/2025 · DFW AIRPORT, TEXAS
## Severity
- **1 hospitalization**
- **Body part:** Lower leg(s)
- **Nature of injury:** Fractures
## Cause
- **Event:** Fall to lower level from collapsing structure or equipment  6 to 30 feet
- **Source:** Hoists, lifts  scissor, telescoping
- **Secondary source:** Vehicle or mobile equipment failure
## Employer
- **Name:** Prism Electric Inc.
- **Location:** 2222 S. Service Rd., DFW AIRPORT, TEXAS, 75261
- **NAICS:** 238210
- **Jurisdiction:** 1
## Narrative

An employee was removing 2-inch conduit from the ceiling of the second floor while standing on a scissor lift elevated 13 feet. There was a failure in the scissor lift and the platform dropped to the bottom position. The employee was hospitalized with a fracture to their right lower leg that required surgery.

---