# Amputations, avulsions, enucleations  unspecified at Montrose Environmental Group, Inc.
> OSHA SIR `2025032107` · 3/5/2025 · BEAUMONT, TEXAS
## Severity
- **1 amputation**
- **Body part:** Finger or thumb tip(s), nail(s)
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Struck by other falling object  n.e.c.
- **Source:** Pipe fittings, collars
- **Secondary source:** Drilling and extraction machinery  n.e.c.
## Employer
- **Name:** Montrose Environmental Group, Inc.
- **Location:** 1705 Burt Street, BEAUMONT, TEXAS, 77703
- **NAICS:** 541620
- **Jurisdiction:** 1
## Narrative

An employee was sampling a fluid catalytic cracking (FCC) unit by opening a valve and placing a proving tube inside to collect the sample. The sample taken is a hot gas mixture. When the sample was collected, the flange came undone and fell due to the pressure. The employee sustained an amputation to their right middle fingertip.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*