# Thermal burns  degree unspecified at Precision Custom Components, LLC
> OSHA SIR `2025032250` · 3/10/2025 · YORK, PENNSYLVANIA
## Severity
- **1 hospitalization**
- **Body part:** Upper and lower extremities  n.e.c.
- **Nature of injury:** Thermal burns  degree unspecified
## Cause
- **Event:** Flash fire
- **Source:** Acetone
- **Secondary source:** Source, secondary source  unspecified
## Employer
- **Name:** Precision Custom Components, LLC
- **Location:** 500 Lincoln Street, YORK, PENNSYLVANIA, 17401
- **NAICS:** 332313
- **Jurisdiction:** 1
## Narrative

An employee was cleaning pans containing adhesive by pouring acetone into the pans. After soaking, the employee used a plastic spatula to scrape the paint from the pan. During scraping, a fire spontaneously started underneath the employee near the pan. The employee threw the container of acetone out of the way to avoid it catching on fire, and spilled acetone onto his clothing, causing the fire to spread. The employee suffered burns to both hands and the right calf.

---