# Fractures at ARS / Rescue Rooter
> OSHA SIR `2025032771` · 3/24/2025 · FRIENDSWOOD, TEXAS
## Severity
- **1 hospitalization**
- **Body part:** Multiple trunk locations
- **Nature of injury:** Fractures
## Cause
- **Event:** Fall to lower level from collapsing structure or equipment  6 to 30 feet
- **Source:** Ceilings
- **Secondary source:** Source, secondary source  unspecified
## Employer
- **Name:** ARS / Rescue Rooter
- **Location:** 4419 Boy Scoutt, FRIENDSWOOD, TEXAS, 77549
- **NAICS:** 238220
- **Jurisdiction:** 1
## Narrative

An employee was looking at a leak in an air conditioner coil when they stepped through the ceiling and fell approximately 10 to 11 feet. The employee was hospitalized with fractures to four ribs, their L1 vertebra, and their pelvis.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*