# Amputations, avulsions, enucleations  unspecified at Piping Rock Health Products, Inc.
> OSHA SIR `2025043726` · 4/22/2025 · FARMINGDALE, NEW YORK
## Severity
- **1 amputation, 1 hospitalization**
- **Body part:** Finger or thumb tip(s), nail(s)
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Struck by running powered equipment  during maintenance, cleaning, testing
- **Source:** Other product testing, inspecting, and diagnostic machinery
- **Secondary source:** Drives, belts, chains
## Employer
- **Name:** Piping Rock Health Products, Inc.
- **Location:** 298 Adams Blvd., FARMINGDALE, NEW YORK, 11735
- **NAICS:** 446191
- **Jurisdiction:** 1
## Narrative

An employee was cleaning an inspection machine when their middle fingertip was caught between the chain and sprocket and amputated.

---