# Amputations, avulsions, enucleations  unspecified at Stalworth Underground LLC
> OSHA SIR `2025043774` · 4/23/2025 · CHICAGO, ILLINOIS
## Severity
- **1 amputation, 1 hospitalization**
- **Body part:** Finger or thumb tip(s), nail(s)
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Caught or wedged between objects  nonrunning
- **Source:** Augers  except conveyor
- **Secondary source:** Rotary system equipment
## Employer
- **Name:** Stalworth Underground LLC
- **Location:** 560 W. Grand Avenue, CHICAGO, ILLINOIS, 60654
- **NAICS:** 238910
- **Jurisdiction:** 1
## Narrative

On April 23, 2025, an employee removed the pin on a Kelly bar to remove it from a drill rig. The auger was lifted to remove the Kelly bar, and the employee's left ring finger was caught in the pin hole. The employee suffered a partial fingertip amputation and was hospitalized.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*