# Amputations, avulsions, enucleations  unspecified at Mobile Energy Battery America, LLC
> OSHA SIR `2025054917` · 5/24/2025 · COMMERCE, GEORGIA
## Severity
- **1 amputation**
- **Body part:** Other finger(s)  n.e.c.
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Struck by running powered equipment  during maintenance, cleaning, testing
- **Source:** Valves, nozzles
- **Secondary source:** Gloves, handguards  except disposable, electric insulating
## Employer
- **Name:** Mobile Energy Battery America, LLC
- **Location:** 1760 SK Blvd, Commerce, GA 30529, COMMERCE, GEORGIA, 30529
- **NAICS:** 335912
- **Jurisdiction:** 1
## Narrative

An employee was demonstrating how to disassemble and reassemble a metal filter unit from the cathode powder transfer line. During the open/close operation of an automated valve, the employee s latex glove became caught. The employee sustained a partial amputation to the left index finger.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*