# Amputations, avulsions, enucleations  unspecified at AR Watson Inc.
> OSHA SIR `2025065466` · 6/9/2025 · CORPUS CHRISTI, TEXAS
## Severity
- **1 amputation**
- **Body part:** Finger or thumb tip(s), nail(s)
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Struck by rolling, sliding, or shifting objects non-running
- **Source:** Beams and rails  metal
- **Secondary source:** Gloves, handguards  except disposable, electric insulating
## Employer
- **Name:** AR Watson Inc.
- **Location:** Citgo Terminal-1802 Poth Lane, CORPUS CHRISTI, TEXAS, 78407
- **NAICS:** 213112
- **Jurisdiction:** 1
## Narrative

An employee was setting an I-beam in place to rest on a 2-inch pipe. Once it was in place, the I-beam rolled back and caught the employee s glove. He suffered an amputation to the right middle fingertip.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*