# Amputations, avulsions, enucleations  unspecified at Fluor Corporation
> OSHA SIR `2025065928` · 6/21/2025 · TATUM, TEXAS
## Severity
- **1 amputation**
- **Body part:** Finger or thumb tip(s), nail(s)
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Struck by running powered equipment  during maintenance, cleaning, testing
- **Source:** Pumps  except oil well
- **Secondary source:** Secondary source not applicable
## Employer
- **Name:** Fluor Corporation
- **Location:** 8850 FM 2658 N, TATUM, TEXAS, 75691
- **NAICS:** 237990
- **Jurisdiction:** 1
## Narrative

An employee was using an air-actuated pump to pump oil from a mill to a 55-gallon drum when the pump malfunctioned. The employee went to fix the pump when it activated and the piston contacted their left index fingertip, resulting in an amputation.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*