# Amputations, avulsions, enucleations  unspecified at Prime Metal Buildings & Components
> OSHA SIR `2025076523` · 7/7/2025 · DUBLIN, TEXAS
## Severity
- **1 amputation, 1 hospitalization**
- **Body part:** Finger or thumb tip(s), nail(s)
- **Nature of injury:** Amputations, avulsions, enucleations  unspecified
## Cause
- **Event:** Struck by running powered equipment  during maintenance, cleaning, testing
- **Source:** Bending, rolling, shaping, stamping machinery  unspecified
- **Secondary source:** Secondary source not applicable
## Employer
- **Name:** Prime Metal Buildings & Components
- **Location:** 19320 US 377, DUBLIN, TEXAS, 76446
- **NAICS:** 332311
- **Jurisdiction:** 1
## Narrative

An employee was operating a double folding machine and positioning a piece of metal trim in the folding clamps for a test bend. The machine activated and the crank (lower control arm that bends the trim) came up and cut through the employee s glove, amputating their right middle fingertip.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · MORVS · CC0 1.0*