# Cuts, lacerations, punctures without injury to internal structures at PCC AIRFOILS, LLC
> OSHA SIR `2025076662` · 7/10/2025 · MENTOR, OHIO
## Severity
- **1 hospitalization**
- **Body part:** Upper arm(s)
- **Nature of injury:** Cuts, lacerations, punctures without injury to internal structures
## Cause
- **Event:** Struck by discharged object or substance
- **Source:** Pressurized water blast
- **Secondary source:** Pressure washers
## Employer
- **Name:** PCC AIRFOILS, LLC
- **Location:** 8607 Tyler Blvd, MENTOR, OHIO, 44060
- **NAICS:** 336412
- **Jurisdiction:** 1
## Narrative

An employee was running a high-pressure water cabinet waterblast unit. When the employee released the wand, it propelled itself out of the blast cabinet. The wand whipped around and the high-pressure water stream lacerated the employee's upper right arm.

---